Rafter Length Calculator
Calculate rafter length, roof angle, and ridge height from building span, roof pitch, and eave overhang.
Advertisement
Full width of building
Rafter Length Formula
Half span = building span / 2. Rise = half span × (pitch / 12). Rafter length = √(half span² + rise²) — the hypotenuse of the roof triangle. Eave overhang is added to the half span before calculating. All dimensions in mm.
Roof pitch (x/12) means x inches of rise per 12 inches of horizontal run. A 4/12 pitch rises 4 mm for every 12 mm of run. The angle = arctan(pitch/12) in degrees.
Worked Examples
- House span 8000 mm, 4/12 pitch, 300 mm overhang: Half span = 4000 + 300 = 4300 mm. Rise = 4300 × (4/12) = 1433 mm. Rafter = √(4300² + 1433²) = 4533 mm (4.53 m). Angle = 18.4°.
- Garage span 6000 mm, 6/12 pitch, no overhang: Half span = 3000 mm. Rise = 3000 × 0.5 = 1500 mm. Rafter = √(3000² + 1500²) = 3354 mm. Angle = 26.6°.
- Extension span 5000 mm, 3/12 pitch, 450 mm overhang: Half span = 2500 + 450 = 2950 mm. Rise = 2950 × 0.25 = 738 mm. Rafter = √(2950² + 738²) = 3041 mm.
Frequently Asked Questions
- What is the standard rafter length for a house?
- For a typical 8–10 m wide Australian house with a 22.5° (5/12) pitch and 300–450 mm overhang, rafter length is typically 4.5–6 m. Rafters are commonly cut from 90×45 mm or 140×45 mm F7 or MGP10 timber, spaced 600–900 mm apart.
- What is the minimum roof pitch for metal roofing?
- Corrugated metal roofing requires a minimum pitch of 5° (about 1/12). Standing seam panels can go as low as 1.5° (1°30'). Tile roofing requires a minimum of 15–17.5° (about 3.2/12 to 3.7/12). Check manufacturer specs and NCC for your material and climate zone.
- How much extra length should I add for the ridge cut and bird's mouth?
- Add 50–100 mm to the calculated rafter length for the ridge plumb cut at the top, and verify bird's mouth depth does not exceed 1/3 of the rafter depth. The overhang field in this calculator handles the eave extension beyond the wall plate.
Advertisement